LÖTMU-DG-RÜCKSCHLAG-VENTIL DN15*RA18 PN5
calcPageSize())"
/>
calcPageSize())"
class="absolute inset-0 object-contain object-center w-full m-auto max-h-screen-75"
:class="{ 'cursor-pointer': !fullscreen }"
width="700"
height="700"
:loading="active!==index ? 'lazy' : 'eager'"
:src="fullscreen ? image.full : image.img"
x-transition.opacity.duration.500ms x-show="active===index"
/>
Click on the product image for a larger view.
calcActive())">
LÖTMU-DG-RÜCKSCHLAG-VENTIL DN15*RA18 PN5
Article-No.: 05412.1518.0001
Price
POR
Description
cryogenic check valve DN15 PN50
cleaned and degreased for oxygen service
working temperature -196°C up to +120°C
body CC491K bronze
bonnet CC493K bronze
spring CW452K bronze opening pressure appr. 0.1bar
connection socket end OD18.0mm
face to face 85mm
height 71mm
seal disc PTFE/25%carbon filled
Leakage rates will be provided on request
cleaned and degreased for oxygen service
working temperature -196°C up to +120°C
body CC491K bronze
bonnet CC493K bronze
spring CW452K bronze opening pressure appr. 0.1bar
connection socket end OD18.0mm
face to face 85mm
height 71mm
seal disc PTFE/25%carbon filled
Leakage rates will be provided on request
Delivery Time:
5 week(s)
More Information
SKU | 05412.1518.0001 |
---|---|
Delivery Time | 5 |
Solution | LNG, Air Gases |
Solution Area | Transport, Storage, Refueling, Processes |
Type (Series) | 05412 |
Maximum allowable temperature | -196.0 °C |
Maximum allowable temperature | 120.0 °C |
cleaned for oxygen service | ISO 23208 |
nominal size | DN 15 |
Nominal pressure | PN 50 |
max. lift | 12.0 |
Kvs-value | 4.3 MQH |
body material | CC491K |
CV-Value | 5,0 gal/min |
China approval | TS2700G39-2025 |
Connection dimension inlet | 18 |
Connection dimension outlet | 18 |
Connection inlet | socked end for copper stubs |
Connection outlet | socket end |
Canada approval | CRN0C229635C |